Logo AUMAAUTHORIZED DISTRIBUTOR

ACTUATORS / PART-TURN ACTUATORS

AUMA SQRVEx Part-Turn Actuator

Part-turn actuators variable speed, explosion-proof, modulating duty

AUMA SQRVEx adalah part-turn actuator variable speed explosion-proof dengan controls ACVExC 01.2 untuk modulating duty, torsi 150 s/d 2,400 Nm, hingga 1,500 starts per jam.AUMA SQRVEx adalah part-turn actuator dengan operating time variabel yang tersertifikasi untuk atmosfer berpotensi ledakan, untuk modulating duty (class C, S4 - 25 %). Dipadukan dengan actuator controls AUMATIC ACVExC 01.2, torsinya 150 s/d 2,400 Nm, modulating torque hingga 1,200 Nm, dan hingga 1,500 starts per jam. Process controller (PID) terintegrasi memungkinkan regulasi langsung di actuator.

SPESIFIKASI UTAMA

  • TORQUE RANGE

    150 s/d 2,400Nm

  • MODULATING TORQUE

    75 s/d 1,200Nm

  • NUMBER OF STARTS

    1,500c/h

  • OPERATING TIME FOR 90°

    4 s/d 360s

  • AMBIENT TEMPERATURE

    -30 to +40/+60°C

  • EXPLOSION PROTECTION

    ATEX, FM, IECEx

SPESIFIKASI LENGKAP

Spesifikasi Teknis AUMA SQRVEx

Ukuran SQRVEx untuk modulating duty

TYPEOPERATING TIME [s]OPERATING TIME FOR 90° [s]TORQUE [Nm]TORQUE RANGE [Nm]MODULATING [Nm]MAX. MODULATING TORQUE [Nm]STARTS [1/h]STARTS MAX. [1/h]FLANGEVALVE ATTACHMENT (EN ISO 5211)
SQRVEx 05.24 s/d 28; 12 s/d 12075 s/d 150751,500F05/F07 (opt. F10)
SQRVEx 07.24 s/d 28; 12 s/d 120150 s/d 3001501,500F05/F07 (opt. F10)
SQRVEx 10.212 s/d 120300 s/d 6003001,500F10 (opt. F12)
SQRVEx 12.224 s/d 240600 s/d 1,2006001,500F12 (opt. F14)
SQRVEx 14.240 s/d 3601,200 s/d 2,4001,2001,500F14 (opt. F16)

Geser untuk melihat kolom lain

Sumber: AUMA Technical data SQRVEx 05.2 s/d 14.2 (modulating duty). Operating time diatur variabel lewat actuator controls ACVExC 01.2.

Detail SQRVEx 05.2 s/d 14.2

FEATURES AND FUNCTIONS

Type of duty
Intermittent duty S4 - 25 %, class C according to EN ISO 22153
Motors
3-phase AC asynchronous squirrel-cage motor, type IM B9 according to IEC 60034-7
Mains voltage
3-phase AC dan 1-phase AC (lihat tabel tegangan di technical data), variation ±10 %
Insulation class
Standard: F, tropicalized. Option: H, tropicalized
Motor protection
Standard: Thermoswitches (NC). Option: PTC thermistors (DIN 44082)
Explosion protection (ATEX)
Standard: II 2G Ex db eb IIC T4 or T3 Gb, II 2G Ex h IIC T4 or T3 Gb (DEKRA 13ATEX0016 X)

SERVICE CONDITIONS

Ambient temperature
Standard: –30 °C to +40 °C/+60 °C. Options: –40 °C or –60 °C to +40 °C/+60 °C, –60 °C to +70 °C
Enclosure protection (IEC 60529)
IP68 with AUMA 3-phase AC motor, terminal compartment double sealed
Corrosion protection
Standard: KS. Option: KX

Sumber: AUMA Technical data SQRVEx 05.2 s/d 14.2.

FITUR

Fitur Utama AUMA SQRVEx

  • Limit and torque sensing
  • Mains connection 1-phase dan 3-phase
  • Handwheel untuk operasi manual
  • Mechanical position indicator

APLIKASI

Area Aplikasi AUMA SQRVEx

SQRVEx dipakai pada control valve seperempat putaran di area berpotensi ledakan yang membutuhkan positioning presisi dengan kecepatan yang dapat diatur, seperti regulasi aliran di plant oil & gas dan kimia.

INDUSTRI

  • Oil & GasManufaktur

DOKUMEN

Dokumen Teknis AUMA SQRVEx

Lihat semua dokumen di situs AUMA

PRODUK TERKAIT

Rekomendasi Produk Terkait

Teknisi TSI melakukan commissioning aktuator AUMA di Fuel Terminal Samarinda

KONSULTASI & LAYANAN

Dukungan Teknis TSI untuk AUMA SQRVEx

Tim engineering TSI membantu sizing dan pemilihan tipe, lalu menangani instalasi, commissioning, service, hingga training di site Anda.

031 9972 8614 | SALES@TS-INSTRUMENT.COM

Area workshop TSI di Sidoarjo

KONSULTASI & LAYANAN

Dukungan Teknis TSI untuk AUMA SQRVEx

Tim engineering TSI membantu sizing dan pemilihan tipe, lalu menangani instalasi, commissioning, service, hingga training di site Anda.

031 9972 8614 | SALES@TS-INSTRUMENT.COM